CAD模型選擇
{negele/druckmessung/lebensmittel_und_getraenke/elektrische_drcukaufnehmer/d3_asmtab.prj},{NB=D31500405004021AP025P025X},{PC=D3},{MRB=-1...35},{MRP=-14.7...500},{OS=1.5 x nominal pressure of measuring element},{ACCD=+/- 0.15% (DIFFURV+TOPURV)},{ACCSO=+/-0.15% (SVURV)},{ACCR=0.05 %},{ACCL=0.2 % URL every 2 years},{TEP=< 0.016 % of calibrated measuring range / 5.5 °C (10 °F)},{TEA=< 0.016 % of calibrated measuring range / 5.5 °C (10 °F)},{TRP=-18...110 °C (0...230 °F), at ambient ? 71 °C (160 °F)},{TRA=-18...71 °C (0...160 °F)},{TRC=130 °C (266 °F) for 1 hour when ambient is below 60 °C (140 °F)},{RT=< 0.2 seconds},{SR=< 0.05 seconds},{CF=1},{TURL=5},{FIT=004},{TCL=0},{BURL=5},{FIT2=004},{CL2=0},{CAP=2},{CL=1},{EC=A},{TPU=P},{TPR=025},{DPU=P},{DPR=025},{Z=X}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
可提供的產品: 1
D31500405004021AP025P025X
HELP_VARIABLE
公司
Anderson-Negele Europe-Asia
描述
D3 - Differential Pressure & Level Transmitter
明细表
D31500405004021AP025P025X
PC
Product Code
D3
CF
Capillary Fill
1 (Mineral Oil/FDA approved)
5 (Neobee/FDA approved)
1 (Mineral Oil/FDA approved)
5 (Neobee/FDA approved)
TURL
Top sensor fittinf / Measurement range of the sensor fitting
5 (0...6 psi; 0...0,4 bar)
6 (30 "Hg/0/30 psi; -1...2 bar)
7 (30 "Hg/0/100 psi; -1...7 bar)
8 (30 "Hg/0/500 psi; -1...35 bar)
5 (0...6 psi; 0...0,4 bar)
6 (30 "Hg/0/30 psi; -1...2 bar)
7 (30 "Hg/0/100 psi; -1...7 bar)
8 (30 "Hg/0/500 psi; -1...35 bar)
FIT
Process connection
004 (1 1/2" Tri-Clamp)
005 (2" Tri-Clamp®)
123 (CPM Standard Fitting)
154 (Endress & Hauser Universal Adaptor - Short)
155 (Endress & Hauser Universal Adaptor - Long)
160 (CLEANadapt G1" with clamping bolt)
182 (CLEANadapt G1" fixed thread)
115 (Milk coupling DIN 11851 DN40)
124 (Milk coupling DIN 11851 DN50)
181 (DRD flange 65 mm)
109 (38mm SMS Liner (female))
110 (51mm SMS Liner (female))
004 (1 1/2" Tri-Clamp)
005 (2" Tri-Clamp®)
123 (CPM Standard Fitting)
154 (Endress & Hauser Universal Adaptor - Short)
155 (Endress & Hauser Universal Adaptor - Long)
160 (CLEANadapt G1" with clamping bolt)
182 (CLEANadapt G1" fixed thread)
115 (Milk coupling DIN 11851 DN40)
124 (Milk coupling DIN 11851 DN50)
181 (DRD flange 65 mm)
109 (38mm SMS Liner (female))
110 (51mm SMS Liner (female))
TCL
Sensor model
0 (Compact version - selectable either for top or bottom sensor fitting)
A (Remote model with 1.5 m (= 5‘) cable)
B (Remote model with 3.0 m (= 10‘) cable)
C (Remote model with 4.5 m (= 15‘) cable)
D (Remote model with 6.0 m (= 20‘) cable)
E (Remote model with 7.5 m (= 25‘) cable)
F (Remote model with 15.0 m (= 50‘) cable)
G (Remote model with 20.0 m (= 65‘) cable)
0 (Compact version - selectable either for top or bottom sensor fitting)
A (Remote model with 1.5 m (= 5‘) cable)
B (Remote model with 3.0 m (= 10‘) cable)
C (Remote model with 4.5 m (= 15‘) cable)
D (Remote model with 6.0 m (= 20‘) cable)
E (Remote model with 7.5 m (= 25‘) cable)
F (Remote model with 15.0 m (= 50‘) cable)
G (Remote model with 20.0 m (= 65‘) cable)
BURL
Bottom sensor fitting / Measurement range of the sensor fitting
5 (0...6 psi; 0...0,4 bar)
6 (30 "Hg/0/30 psi; -1...2 bar)
7 (30 "Hg/0/100 psi; -1...7 bar)
8 (30 "Hg/0/500 psi; -1...35 bar)
5 (0...6 psi; 0...0,4 bar)
6 (30 "Hg/0/30 psi; -1...2 bar)
7 (30 "Hg/0/100 psi; -1...7 bar)
8 (30 "Hg/0/500 psi; -1...35 bar)
FIT2
Process connection
004 (1 1/2" Tri-Clamp)
005 (2" Tri-Clamp®)
123 (CPM Standard Fitting)
154 (Endress & Hauser Universal Adaptor - Short)
155 (Endress & Hauser Universal Adaptor - Long)
160 (CLEANadapt G1" with clamping bolt)
182 (CLEANadapt G1" fixed thread)
115 (Milk coupling DIN 11851 DN40)
124 (Milk coupling DIN 11851 DN50)
181 (DRD flange 65 mm)
109 (38mm SMS Liner (female))
110 (51mm SMS Liner (female))
004 (1 1/2" Tri-Clamp)
005 (2" Tri-Clamp®)
123 (CPM Standard Fitting)
154 (Endress & Hauser Universal Adaptor - Short)
155 (Endress & Hauser Universal Adaptor - Long)
160 (CLEANadapt G1" with clamping bolt)
182 (CLEANadapt G1" fixed thread)
115 (Milk coupling DIN 11851 DN40)
124 (Milk coupling DIN 11851 DN50)
181 (DRD flange 65 mm)
109 (38mm SMS Liner (female))
110 (51mm SMS Liner (female))
CL2
Sensor model
0 (Compact version - selectable either for top or bottom sensor fitting)
A (Remote model with 1.5 m (= 5‘) cable)
B (Remote model with 3.0 m (= 10‘) cable)
C (Remote model with 4.5 m (= 15‘) cable)
D (Remote model with 6.0 m (= 20‘) cable)
E (Remote model with 7.5 m (= 25‘) cable)
F (Remote model with 15.0 m (= 50‘) cable)
G (Remote model with 20.0 m (= 65‘) cable)
0 (Compact version - selectable either for top or bottom sensor fitting)
A (Remote model with 1.5 m (= 5‘) cable)
B (Remote model with 3.0 m (= 10‘) cable)
C (Remote model with 4.5 m (= 15‘) cable)
D (Remote model with 6.0 m (= 20‘) cable)
E (Remote model with 7.5 m (= 25‘) cable)
F (Remote model with 15.0 m (= 50‘) cable)
G (Remote model with 20.0 m (= 65‘) cable)
CAP
Enclosure cap
2 (Clear plastic)
3 (Closed stainless steel)
2 (Clear plastic)
3 (Closed stainless steel)
CL
Housing orientation / Connectors
1 (ABC)
2 (ACB)
3 (BAC)
4 (BCA)
5 (CAB)
6 (CBA)
1 (ABC)
2 (ACB)
3 (BAC)
4 (BCA)
5 (CAB)
6 (CBA)
EC
Electrical connection
A (M12 plug)
C (Cable gland M16x1.5)
A (M12 plug)
C (Cable gland M16x1.5)
TPU
Top Pressure Units
P (psi)
B (Bar)
W (in H2O)
L (mbar)
X (mm H2O)
P (psi)
B (Bar)
W (in H2O)
L (mbar)
X (mm H2O)
TPR
Top pressure calibration range
025 (30 "Hg/0)
304 (30 "Hg/0/7)
028 (30 "Hg/0/15)
029 (30 "Hg/0/30)
031 (30 "Hg/0/60)
032 (30 "Hg/0/100)
314 (30 "Hg/0/200)
501 (0...1,2)
428 (0...1,5)
057 (0...2)
235 (0...3)
192 (0...4)
060 (0...6)
309 (0...7)
061 (0...10)
502 (0...18)
065 (0...20)
066 (0...30)
224 (0...35)
067 (0...40)
068 (0...50)
069 (0...60)
206 (0...70)
071 (0...100)
294 (0...140)
073 (0...150)
074 (0...160)
075 (0...200)
077 (0...300)
078 (0...350)
079 (0...400)
503 (0...415)
504 (0...480)
081 (0...500)
000 (Unrestricted measurement range as per sensor fitting)
999 (Factory setting as per customer specification)
025 (30 "Hg/0)
304 (30 "Hg/0/7)
028 (30 "Hg/0/15)
029 (30 "Hg/0/30)
031 (30 "Hg/0/60)
032 (30 "Hg/0/100)
314 (30 "Hg/0/200)
501 (0...1,2)
428 (0...1,5)
057 (0...2)
235 (0...3)
192 (0...4)
060 (0...6)
309 (0...7)
061 (0...10)
502 (0...18)
065 (0...20)
066 (0...30)
224 (0...35)
067 (0...40)
068 (0...50)
069 (0...60)
206 (0...70)
071 (0...100)
294 (0...140)
073 (0...150)
074 (0...160)
075 (0...200)
077 (0...300)
078 (0...350)
079 (0...400)
503 (0...415)
504 (0...480)
081 (0...500)
000 (Unrestricted measurement range as per sensor fitting)
999 (Factory setting as per customer specification)
DPU
Differential pressure units
P (psi)
B (Bar)
W (in H2O)
L (mbar)
X (mm H2O)
P (psi)
B (Bar)
W (in H2O)
L (mbar)
X (mm H2O)
DPR
Differential pressure calibration range
025 (30 "Hg/0)
304 (30 "Hg/0/7)
028 (30 "Hg/0/15)
029 (30 "Hg/0/30)
031 (30 "Hg/0/60)
032 (30 "Hg/0/100)
314 (30 "Hg/0/200)
501 (0...1,2)
428 (0...1,5)
057 (0...2)
235 (0...3)
192 (0...4)
060 (0...6)
309 (0...7)
061 (0...10)
502 (0...18)
065 (0...20)
066 (0...30)
224 (0...35)
067 (0...40)
068 (0...50)
069 (0...60)
206 (0...70)
071 (0...100)
294 (0...140)
073 (0...150)
074 (0...160)
075 (0...200)
077 (0...300)
078 (0...350)
079 (0...400)
503 (0...415)
504 (0...480)
081 (0...500)
000 (Unrestricted measurement range as per sensor fitting)
999 (Factory setting as per customer specification)
025 (30 "Hg/0)
304 (30 "Hg/0/7)
028 (30 "Hg/0/15)
029 (30 "Hg/0/30)
031 (30 "Hg/0/60)
032 (30 "Hg/0/100)
314 (30 "Hg/0/200)
501 (0...1,2)
428 (0...1,5)
057 (0...2)
235 (0...3)
192 (0...4)
060 (0...6)
309 (0...7)
061 (0...10)
502 (0...18)
065 (0...20)
066 (0...30)
224 (0...35)
067 (0...40)
068 (0...50)
069 (0...60)
206 (0...70)
071 (0...100)
294 (0...140)
073 (0...150)
074 (0...160)
075 (0...200)
077 (0...300)
078 (0...350)
079 (0...400)
503 (0...415)
504 (0...480)
081 (0...500)
000 (Unrestricted measurement range as per sensor fitting)
999 (Factory setting as per customer specification)
Z
Certificate
X (No certificate)
Z (3.1 material certificate and calibration certificate of the stem)
X (No certificate)
Z (3.1 material certificate and calibration certificate of the stem)